Sbi BS En13823 Single Burning Item for Flame Retardant Testing

Product Details
After-sales Service: Response on Customers′ Questions Within 12 Hours.
Warranty: 12 Months
Reference Standards: ISO 9239-1, ASTM E648-17
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
1000000 RMB
Plant Area
>2000 square meters
  • Sbi BS En13823 Single Burning Item for Flame Retardant Testing
  • Sbi BS En13823 Single Burning Item for Flame Retardant Testing
  • Sbi BS En13823 Single Burning Item for Flame Retardant Testing
  • Sbi BS En13823 Single Burning Item for Flame Retardant Testing
  • Sbi BS En13823 Single Burning Item for Flame Retardant Testing
  • Sbi BS En13823 Single Burning Item for Flame Retardant Testing
Find Similar Products
  • Overview
  • Product Description
  • Reference Standards
  • Features
  • Product Parameters
  • Testing Results
  • Detailed Photos
Overview

Basic Info.

Model NO.
SBI
Control Mode
Computer Control
Application
Test Reaction to Fire Behavior of Building Product
Application Field
Building Material
Item Name
Sbi BS En13823 Single Burning Item
Apparatus Dimension
3000 mm (W) X 4500 mm (H) X 3000 mm
Power Supply
220V, 10A, 50Hz
Features
En 13823 Standard Single Burning Item Sbi Tester
Delivery Lead Time
2 Months
Trade Term
EXW, Fob, DDU, CNF, CIF, etc.
Payment Term
30% T/T as Deposit, The Balance Before Delivery
Conditon
Totally New
Shipping Method
by Sea
Packing
in Container
Language
English
Transport Package
Single Burning Item Is Packed in Veneer Casse
Specification
3000 mm (W) x 4500 mm (H) x 3000 mm
Trademark
DELTA
Origin
China
HS Code
9031809090
Production Capacity
10 Sets Single Burning Item /Month

Product Description

SBI SBI BS EN13823 Single Burning Item For Flame Retardant Testing
Product Description
  1. The SBI BS EN13823 Single Burning Item is a method of test for determining the reaction to fire behavior of building products (excluding floorings) when exposed to the thermal attack by a single burning item (a sand-box burner supplied with propane).
  2. The specimen is mounted on a trolley that is positioned in a frame beneath an exhaust system. The reaction of the specimen to the burner is monitored instrumentally and visually. Heat and smoke release rates are measured instrumentally and physical characteristics are assessed by observation.
Sbi BS En13823 Single Burning Item for Flame Retardant Testing

 

Reference Standards
  • EN 13501;
  • EN 13823;
Features
  • The SBI BS EN13823 Single Burning Item consists of a trolley, a fixed frame, a gas collecting hood, collector, J type exhaust pipe, centrifugal fan, wind speed control device, the comprehensive measurement section, gas analysis cabinet, data acquisition system;
  • The trolley can be installed with two vertical sample specimens. The bottom of the vertical angle is a sand box burner. The surface ignition method is adopted, and the flame detection system is equipped as a flameout protection device;
  • The fixed frame support the gas collecting hood. The frame is fixed with an auxiliary burner and equipped with a flame detecting system as a flameout protection device;
  • Stainless steel gas collector, located at the top of the fixed frame, used to collect combustion gases;
  • Stainless steel J type smoke exhaust pipe, the inner diameter is (315 + 5) mm  with 50mm high temperature resistant mineral cotton insulation;
  • The smoke exhaust system shall continuously exhaust smoke at the speed of 0.50m3/s-0.65 m3/s, and be regulated by frequency conversion;
  • Mass flow controller, measuring range of 0g/s-2.5g/s, reading accuracy of not less than 1.5%;
  • Gas supply can be automatically controlled to flow rate of 647mg/s and 2000mg/s, the gas control system can guarantee the speed of gas supply in the process of test changes should not exceed 5mg/s, to ensure the heat output of 30.7 + 2kW;
  • The flue gas sampling system consists of an ash filter, a cold trap, two drying columns, a sampling pump and a peristaltic pump, so as to effectively make sample gas clean and dry;
  • Paramagnetic oxygen analyzer, measuring range of 0-25%, measuring oxygen concentration in the gas, the concentration range of 0-25%, T90<12 seconds; Non dispersive infrared CO2 analyzer: CO2:0 ~ 10%;
  • A pipeline with a length of 2155mm, equipped with a pressure probe, three thermocouples, a gas sampling probe, and a white light system;
  • Two-way probe, with the range of at least (0-100) Pa and accuracy of 2Pa inlet pressure sensor connected. The response time of the pressure sensor 90% output is at most 1s;
  • The light system is incandescent type, with (2900 + 100) K color temperature,and the flexible joint is installed on the side of the exhaust pipe;
  • Silicon photodiode detector, with 0.1% linear stability;
  • The air is introduced into the side tube to maintain the cleanliness of the optical device, which can be accomplished by compressed air;
Product Parameters
No. Item Name SBI BS EN13823 Single Burning Item
1 Dimension 3000 mm (W) x 4500 mm (H) x 3000 mm
2 Weight 650kg


Software Features:

Provide the following calibration and operation interface:
  • O2/CO2 analyzer calibration: O2/CO2 output noise and drift calibration
  • Calibration of optical systems: noise and drift calibration of smoke measurement systems
  • Optical system calibration: filter calibration
  • Air volume calibration: air volume control range calibration
  • Ladder calibration and heptane calibration
Heat output ladder calibration meet the following requirements:
  • The delay time of the O2/CO2 analyzer is not more than 30s;
  • The response time of the O2/CO2 analyzer is not more than 12s;
  • The response time of the burner switch is not more than 12s;
  • The temperature response time shall not exceed 6s;
  • The ratio Q gas 30s (T) /HRR30s (T), (T) should be continuous (100 + 5)%;
  • The difference between the average of HRR step 2 and the average of HRR step 3 is not more than 0.5kW.
Heptane calibration results:
The calorific value of unit mass heptane should be THR/m (4456 + 222.8) MJ/kg;

 
Testing Results
  • Average rate of heat release[RHRav(t)]

    Total Heat Release[THR(t)]

    1000 * [RHRav(t)/(t-300)]

    Fire Growth Rate Index[FIGRA]

    Total Heat Release[THR600s]

    Occurrence of Lateral Flame Spread
    RSPav(t)

    Total Smoke Production[TSP(t)]

    10000 * [RSPav(t)/(t-300)]

    Smoke Growth Rate Index[SMOGRA]

    Total Smoke Production[TSP600s]
    Sbi BS En13823 Single Burning Item for Flame Retardant Testing
     
    Detailed Photos
    Sbi BS En13823 Single Burning Item for Flame Retardant Testing
    Sbi BS En13823 Single Burning Item for Flame Retardant Testing

    Sbi BS En13823 Single Burning Item for Flame Retardant TestingSbi BS En13823 Single Burning Item for Flame Retardant Testing

Please contact us for quotation and more technical information.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier