• Transformer Cable Gis AC Withstand Voltage Testing Hipot Resonant Test Set
  • Transformer Cable Gis AC Withstand Voltage Testing Hipot Resonant Test Set
  • Transformer Cable Gis AC Withstand Voltage Testing Hipot Resonant Test Set
  • Transformer Cable Gis AC Withstand Voltage Testing Hipot Resonant Test Set
  • Transformer Cable Gis AC Withstand Voltage Testing Hipot Resonant Test Set
  • Transformer Cable Gis AC Withstand Voltage Testing Hipot Resonant Test Set

Transformer Cable Gis AC Withstand Voltage Testing Hipot Resonant Test Set

After-sales Service: Response on Customer′s Query Within 8 Hours
Warranty: 1 Year
Max Diameter of Workpiece: <500mm
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Transformer Cable Gis AC Withstand Voltage Testing Hipot Resonant Test Set pictures & photos
Transformer Cable Gis AC Withstand Voltage Testing Hipot Resonant Test Set
US $2,000-20,000 / Set
Min. Order: 1 Set
Gold Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Product Description
  • Product Parameters
  • Features
  • Detailed Photos
Overview

Basic Info.

Model NO.
XZ
Mass Scope of Workpiece
<900kg
Type
Compression Testing Machine
Maxcapacity
<1000KN
Accuracy Grade
0.1
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Digital
Control
Manual Control
Weight
0-100Kg
Power Source
AC220V
Oil Cylinder Position
Under
Resonate Voltage Waveform
Sine Wave
Output Frequency
30~300Hz
Quality Factor
30~80
Rated Output Voltage
27kv /54kv /108kv
Application
Supply High Voltage for Testing
Output Voltage Power Supply
Single Phase 380/220V, 50Hz
Working Mode
Full Power Continuous Working Time, 60min
Protection
Over Current, Over Voltage, Arc Protection,
Description
35kv Switchgear Busbar Gis Hipot Testing Equipment
Power Supply
AC 220V, 50Hz/60Hz
Delivery Lead Time
20 Days After The Order Is Confirmed
Shipping Method
Suggest to Ship by Air or Courier
Trade Terms
EXW, Fob, DDU, CIF, etc.
Language
English
OEM Service
Yes
Transport Package
Packed in Plywood Case
Specification
Withstand Voltage Testing Hipot Resonant Test Set
Trademark
Delta
Origin
China Mainland
HS Code
9031809090
Production Capacity
10 Sets Resonant Test Set / Month

Packaging & Delivery

Package Size
100.00cm * 100.00cm * 100.00cm
Package Gross Weight
100.000kg

Product Description

XZ Transformer Cable GIS AC Withstand Voltage Testing Hipot Resonant Test Set

Product Description

It uses an excitation transformer to motivate series resonant loop, to adjust the output frequency of the director, make the loop inductance L, and measured equipment C in series resonant, the voltage of the resonance is the same as tested equipment.

XZ Transformer Cable GIS AC Withstand Voltage Testing Hipot Resonant Test Set is widely used in Electric Power, Metallurgy, Oil, Chemical Industry, etc, applicable to connecting and preventing tests for capacitive equipment with high-capacity, high-voltage.

Its main function is to change 380V or 200V (the amplitude and frequency are fixed) frequency sine wave AC power into sine wave (amplitude and frequency are adjustable), and supply power for the whole system.

The function of the excitation transformer is to boost the output voltage of the power source to the proper measured voltage. High voltage reactor L is an important component of the resonant loop, it with measured equipment CX in serial resonant when the power frequency=1/(2π )
XZ 35kV Switchgear Busbar Hipot Testing Equipment, GIS Hipot Testing Equipment applies to AC voltage withstand tests of 10KV, 35KV, 110KV, 220KV, 500KV polythene cable, 60KV, 220KV, 500KV GIS, large transformers, generators, transformer induced voltage withstand test, and ground resistance measurement.
 

XZ Transformer Cable GIS AC Withstand Voltage Testing Hipot Resonant Test Set is composed by:
one control cabinet
excitation transformer
high voltage reactor
one high voltage divider

There are two kinds of control cabinets, more than 20KW is a console, less than 20KW is a portable case; it is composed of controller and filter device.
 
Transformer Cable Gis AC Withstand Voltage Testing Hipot Resonant Test Set

 

Product Parameters
No. Item XZ Transformer Cable GIS AC Withstand Voltage Testing Hipot Resonant Test Set
1 Resonate voltage waveform Sine wave, distortion ≤1%
2 Output frequency 30~300Hz
3 Working mode Full power continuous working time, 60min
4 Quality factor 30~80
5 Output voltage power supply single phase 380/220V±10%, 50Hz
6 Working environment -10ºC~+50ºC, Relative humidity < 95%

 

Features

High stability and reliability. Voltage and frequency output is stable, design for electromagnetic compatibility is reasonable, perfect protecting protection, the system is still good after several tests high voltage to earth short circuit , meanwhile the system with strong over-load ability.

Powerful automatic tuning function. When the system automatic tuning, auto scanning from 30Hz to 300Hz, display the scanning curve, customers can clearly view the tuning process; after finished the scanning, system will find out the resonant point, makes frequency fine tuning within its range ±5Hz with resolution 0.01Hz, finally accurately lock the resonant frequency.

Multi test modes: automatic tuning + manually regulating voltage, automatic tuning + automatic regulating voltage, manually tuning + manually regulating voltage, we suggest the mode: automatic tuning + manually regulating voltage, which can fast find out the resonant point, it also can control the measurement process by manually regulating voltage, more safe.

Friendly man-machine communication interface, parameters setting, test controlling , test results displayed in one screen, clear and visible, with auto timing and operation indicating functions, full touching screen, can store and review the test data.

Perfect protecting functions, with zero position protection (forbid the system to start if the voltage output controlling knob was not at the zero position), over-voltage protection, over-current protection and flashover protection, ensure the safety of the system.

Detailed Photos
Transformer Cable Gis AC Withstand Voltage Testing Hipot Resonant Test Set
Transformer Cable Gis AC Withstand Voltage Testing Hipot Resonant Test Set


Transformer Cable Gis AC Withstand Voltage Testing Hipot Resonant Test Set
Transformer Cable Gis AC Withstand Voltage Testing Hipot Resonant Test Set
Transformer Cable Gis AC Withstand Voltage Testing Hipot Resonant Test Set

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Transformer Cable Gis AC Withstand Voltage Testing Hipot Resonant Test Set pictures & photos
Transformer Cable Gis AC Withstand Voltage Testing Hipot Resonant Test Set
US $2,000-20,000 / Set
Min. Order: 1 Set
Gold Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Registered Capital
1000000 RMB
Plant Area
>2000 square meters