CCT Cone Calorimeter ISO5660 ASTM E1354 BS476-15

Product Details
After-sales Service: Lifetime
Warranty: 12 Months
Reference Standards: ISO5660, ASTM E1354, BS476-15
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
1000000 RMB
Plant Area
>2000 square meters
  • CCT Cone Calorimeter ISO5660 ASTM E1354 BS476-15
  • CCT Cone Calorimeter ISO5660 ASTM E1354 BS476-15
  • CCT Cone Calorimeter ISO5660 ASTM E1354 BS476-15
  • CCT Cone Calorimeter ISO5660 ASTM E1354 BS476-15
  • CCT Cone Calorimeter ISO5660 ASTM E1354 BS476-15
  • CCT Cone Calorimeter ISO5660 ASTM E1354 BS476-15
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
Overview

Basic Info.

Model NO.
CCT
Application Field
Building Material, Railway, Marine, Cable, etc.
Application
for Material Burning Performance Testing
Features
ISO5660, ASTM E1354, BS476-15 Cone Calorimeter
Conical Heater
5000 W, Output 100 Kw/M2
Temperature Controller
3 Type K Thermocouples and a 3-Term (Pid)
Operation Method
Through Computer, PLC Control
Item Name
Cone Calorimeter ISO5660 ASTM E1354 BS476-15
Working Gas
Compressed Air
Calibration Gas
CH4, N2, CO2/Co Mixed Gas
Gas Feed Unit
ABB Brand
PLC Brand
Omron
Dimension
1800mm (W) X 900mm X (H) X 2600mm (D)
Power Supply
220V, 50Hz
OEM Service
Available
Transport Package
Cone Calorimeter Packed in Container
Specification
350kg
Trademark
Delta
Origin
China
HS Code
9031809090
Production Capacity
10 Sets Cone Calorimeter / Month

Product Description

CCT Cone Calorimeter ISO5660 ASTM E1354 BS476-15
Product Description
It is designed and manufactured according to international standards, mainly for building products and testing electric cables.

The analysis cabinet of our CCT Cone Calorimeter ISO5660 ASTM E1354 BS476-15 can be moved, it can be used for cone calorimeter test, and it can also be used in the large heat release rate test system such as Single Burning Item(SBI), cable burning test system, etc.
Product Parameters

Measured properties:

  1. Heat release rate;
  2. Flue gas flow rate;
  3. C coefficient;
  4. Time to ignition;
  5. Extinction time;
  6. Total oxygen consumption;
  7. Smoke release rate;
  8. Mass loss rate;
  9. Effective heat of combustion;
  10. Rates of release of combustion gas (e.g. CO and CO2)
  11. No. Item Name CCT Cone Calorimeter ISO5660 ASTM E1354 BS476-15
    1 Dimension 1800mm (W) x 900mm x (H) x 2600mm (D)
    2 Weight 350kg
    3 Power supply 220V, 50Hz
    4 Ambient temperature 10 ~ 35 Centigrade
    5 Working gas Compressed air
    6 Calibration gas CH4, N2, CO2/CO mixed gas

Application Field:
  1. Building products;
  2. Railway rolling-stock applications;
  3. Maritime applications;
  4. Electric cables;
  5. Etc;

Features:
  1. Integrated body and 19" analysis rack, 15" touch screen panel type PC for the whole control and automatic testing
  2. Conical Heater - is wound in the form of a truncated cone, rated 5000 W at 230 V with a heat output of 100 kW/m2.
  3. Facility for testing horizontally or vertically orientated specimens
  4. Temperature control by the use of a 3 type K thermocouples and a 3-term (PID) temperature controller.
  5. Auto Split Shutter automatically opened to transmit radiation to the sample, Automatic Spark Igniter to facilitate measurement of ignition time
  6. Specimen Holders - for specimens 100mm x 100mm up to 50mm thick, in the horizontal and vertical orientation.
  7. Load Cell - mass measurements are conducted via a strain gauge load cell with an accuracy of 0.1g. Fitted with a quick electronic tare facility and mechanical stops to avoid movement damage, give stable results and long life.
  8. Exhaust System - manufactured from stainless steel for long life. This comprises, hood, gas sampling ring probe, exhaust fan (with adjustable flow controls from 0-50g/s, at a resolution of at least 0.1g/s) and an orifice plate flow measurement (thermocouple and differential pressure transducer). Normal operation is at a nominal 24 l/s.
  9. ABB Gas feed unit, Model SCC-S, including 1 gas path, condensate monitor, pump and flow controller with needle valve Peltier cooler and condensate pump. SCC-S can remove water automatically.
  10. ABB EL3020-Uras26+ Magnos206, CO 0-1%, CO2 0-10%, automatic calibration of CO & CO2, does not require the use of mixture of CO&CO2 gas. O2 0-25%, Only once a month is used to calibrate the zero point with the nitrogen,
  11. Smoke Obscuration - measured with a laser system, using photodiodes, and a 0.5 mW Helium Neon laser, with main and reference (compensating) photo detectors. Supplied with alignment cradle and 0.3, 0.8 neutral density filters for calibration.
  12. Medtherm Heat Flux Meter - for setting the irradiance level at the surface of the specimens, the range from 0-100KW/m2.
  13. Provide the Self circulation cooling water to cool heat flux meter, without External tap water.
  14. Calibration Burner - to calibrate the rate of heat release measured by the apparatus using methane of 99.5% purity.
  15. Methane MFC, to control the flow rate of Methane automatically.
  16. OMRON PLC to control all movement such as Split Shutter, Spark Igniter etc.
  17. DAQ(Data Acquisition) Program controllable with the touch screen panel PC
  18. Provide 10units of PMMA samples for comparison testing.
CCT Cone Calorimeter ISO5660 ASTM E1354 BS476-15
CCT Cone Calorimeter ISO5660 ASTM E1354 BS476-15
CCT Cone Calorimeter ISO5660 ASTM E1354 BS476-15
CCT Cone Calorimeter ISO5660 ASTM E1354 BS476-15
CCT Cone Calorimeter ISO5660 ASTM E1354 BS476-15
CCT Cone Calorimeter ISO5660 ASTM E1354 BS476-15
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier