After-sales Service: | Online Training for Operation and Installation |
---|---|
Warranty: | One Year |
Compliance: | ISO 6942, En 366 |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Method A | The specimen is mounted in the specimen holder vertically and exposed to the specific radiant heat source for a time. Adjust the distance between the specimen and the radiant heat source, and examine the visible changes on the specimen for determining the behavior of the material for heat protective performance. |
Method B | The specimen is mounted in the specimen holder vertically and exposed to a specific level of radiant heat. Measure the time for the temperature sires of 12 degrees and 24 degrees by the calorimeter behind the specimen. The radiant heat transfer indexes, and percentage heat transmission factor are calculated from the temperature rise data and are served to evaluate the specimen heat protective performance. |
No. | Item Name | RPP Protective Clothing Radiant Protective Test Device ISO 6942 EN366 |
1 | Dimension | 1350mm * 750mm * 1250mm |
2 | Weight | 160kg |
3 | Power supply | 220V, 50Hz, 70A |
4 | Air requirement | Compressed air |