No. | Item Name | FTIR Fourier Infrared Flue Gas Toxicity Tester |
General Parameters | ||
1 | Measuring principle | FTIR (Fourier transform infrared) |
2 | Performance | Simultaneous analysis of up to 50 gas components |
3 | Operating temperature | 20 ± 20 °C, non-condensing, dust-free ambient air |
4 | Storage temperature | -20 - +60 °C |
5 | Response time | T90: < 120 s, depending on the gas flow and measurement time |
6 | Gas cell temperature | 50-180 °C |
7 | Sample gas | Non-condensing, particle-free |
8 | Flow rate | 0~ 4 l/min |
9 | Sample gas pressure | Ambient |
Measuring Parameters | ||
10 | Zero point calibration | 24 hours, calibration with nitrogen(5.0 or higher N2 recommended) |
11 | Zero point drift | < 2 % of measuring range per zero point calibration interval |
12 | Sensitivity drift | None |
13 | Linearity deviation | < 2 % of measuring range |
14 | Temperature drifts | < 2 % of measuring range per 10K temperature change |
15 | Pressure influence | 1% change of measuring value for 1% sample pressure change. Ambient pressure changes measured and compensated |
System Alarm | ||
Gasmet FTIR gas analyzer and Calumet application software Gasmet FTIR gas analyzer and Calumet application software. Heated module temp. low/high Line 1 temperature low/high Line 2 temperature low/high. Line 3 temperature low/high Flow alarm low. Zero gas pressure is low. |
||
Heated Lines | ||
Tube size | 4/6 mm | |
Core material | Teflon core | |
Operating pressure | Maximum 400 kPa | |
Temperature | Maximum 200 ºC | |
Fittings | 6 mm Swagelok | |
Power supply | 230 VAC or 115 VAC | |
Power density | 120 watts /meter | |
The maximum length for the heated line is 30 m with 230 VAC and 15 m with 115 VAC power supply. All analysers are connected together with 1 m heated lines. Other lengths over 30 m (230 VAC) and temperatures are available on request. | ||
Sample probe | ||
Sample probe | PSP4000H | |
Power consumption | 800 watts | |
Operating temperature | 180 ºC | |
Filter element | Ceramic, 2 μm | |
Dust loading | < 2 g/m3 Probe tube | |
Material | SS 316 | |
Probe length | One (1) meter | |
Sample temperature | 600 ºC max | |
Sample pressure | 0.4 to 6 bar | |
Mounting flange | DN65PN6 | |
Electrical connections | ||
Main supply | 3 x 16 A, 3 x L+N+PE | |
Power consumption | 7,5 kW (the full Gasmet CEMS including FTIR gas analyzer, PC, sampling unit, Gasmet O2 analyzer, sample probe, and heated lines 21 m) |