• Ftir Fourier Transform Infrared Flue Gas Toxicity Testing Device
  • Ftir Fourier Transform Infrared Flue Gas Toxicity Testing Device
  • Ftir Fourier Transform Infrared Flue Gas Toxicity Testing Device
  • Ftir Fourier Transform Infrared Flue Gas Toxicity Testing Device
  • Ftir Fourier Transform Infrared Flue Gas Toxicity Testing Device
  • Ftir Fourier Transform Infrared Flue Gas Toxicity Testing Device

Ftir Fourier Transform Infrared Flue Gas Toxicity Testing Device

After-sales Service: Online Training, Reply Customer′s Question in 12h
Warranty: 12 Months
Measuring Principle: Fourier Transform Infrared, Ftir
Performance: Simultaneous Analysis of up to 50 Gas Components
Brand: Gasmet
Response Time: < 120 S
Gold Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
FTIR
Flow Rate
0 - 4 L/Min
Sample Gas
Non-Condensing, Particle-Free
Sample Probe
PSP4000h
Zero Point Calibration
Calibration with Nitrogen
Filter Element
Ceramic, 2um
Gas Cell Temperature
50-180 Centigrade
Features
High Quality Ftir Gas Toxicity Testing Device
Type
Fire Testing Equipment
Operation Mode
Automatic
Display
Digital Display
Language
English
Transport Package
Ftir Is Packed in One Plywood Case
Specification
FTIR Fourier Infrared Flue Gas Toxicity Tester
Trademark
Delta
Origin
China Mainland
HS Code
9031809090
Production Capacity
100 Sets / Month

Product Description

FTIR Fourier Infrared Flue Gas Toxicity Testing Device


Introduction:
  • The Gasmet FTIR analyzer is an ideal tool for toxicity tests in fire testing applications. It can be used in conjunction with the Cone Calorimeter, and NBS Smoke Density Chamber for online measurements of combustion gases in fire tests.
  • Typical application for CEM is H2O, CO2, CO, N2O, NO, NO2,SO2, HCl, HF, NH3, CH4, C2H6, C3H8, and C2H4. The Gasmet FTIR can be easily configured for a new set of compounds.
  • Measured components and calibration ranges can be changed according to application. This technical data sheet describes one example of the system.
  • The system is used for on-line measurements. It is an ideal tool to use for measuring trace concentrations of gas in combustion studies. All parts of the Gasmet CEMS are heated up to 180 ºC. It can be used for undiluted gases and the sample gases do not need drying beforehand.
  • The Gasmet FTIR system consists of a Gasmet gas analyzer- it is configured to meet ISO 19702 standard, Gasmet PC, and Gasmet sampling system. All parts of the system are 19" rack-mounted cabinets.
  • The Gasmet FTIR system includes all power connections and temperature controllers for heated lines and heated sample probes. The operation of the system is fully automatic and controlled by the Calcmet software.
  • Gasmet PC and Calumet application software control the system. The measuring data can be transferred from the PC to the Control room with digital outputs (ModBus) or with analog outputs 4-20 mA.
  • The Gasmet FTIR system provides different alarm functions such as Function alarm, Service alarm, and System alarm. Function and service alarms are associated with the Gasmet FTIR Gas Analyzer and with the Calumet analysis software. A system alarm comes from the Gasmet sampling system and it includes temperature alarms (from sample probe, heated lines, and sampling unit), flow alarms, and pressure alarms for zero gas. If any of the critical alarms are activated, instrument air starts to flow automatically into the system to prevent condensation.
Parameters:
No. Item Name FTIR Fourier Infrared Flue Gas Toxicity Tester
General Parameters
1 Measuring principle FTIR (Fourier transform infrared)
2 Performance Simultaneous analysis of up to 50 gas components
3 Operating temperature 20 ± 20 °C, non-condensing, dust-free ambient air
4 Storage temperature -20 - +60 °C
5 Response time T90: < 120 s, depending on the gas flow and measurement time
6 Gas cell temperature 50-180 °C
7 Sample gas Non-condensing, particle-free
8 Flow rate 0~ 4 l/min
9 Sample gas pressure Ambient
Measuring Parameters
10 Zero point calibration 24 hours, calibration with nitrogen(5.0 or higher N2 recommended)
11 Zero point drift < 2 % of measuring range per zero point calibration interval
12 Sensitivity drift None
13 Linearity deviation < 2 % of measuring range
14 Temperature drifts < 2 % of measuring range per 10K temperature change
15 Pressure influence 1% change of measuring value for 1% sample pressure change. Ambient pressure changes measured and compensated
System Alarm
  Gasmet FTIR gas analyzer and Calumet application software
Gasmet FTIR gas analyzer and Calumet application software. Heated module temp. low/high Line 1 temperature low/high Line 2 temperature low/high.
Line 3 temperature low/high Flow alarm low.
Zero gas pressure is low.
Heated Lines
  Tube size 4/6 mm
  Core material Teflon core
  Operating pressure Maximum 400 kPa
  Temperature Maximum 200 ºC
  Fittings 6 mm Swagelok
  Power supply 230 VAC or 115 VAC
  Power density 120 watts /meter
  The maximum length for the heated line is 30 m with 230 VAC and 15 m with 115 VAC power supply. All analysers are connected together with 1 m heated lines. Other lengths over 30 m (230 VAC) and temperatures are available on request.
Sample probe
  Sample probe PSP4000H
  Power consumption 800 watts
  Operating temperature 180 ºC
  Filter element Ceramic, 2 μm
  Dust loading < 2 g/m3 Probe tube
  Material SS 316
  Probe length One (1) meter
  Sample temperature 600 ºC max
  Sample pressure 0.4 to 6 bar
  Mounting flange DN65PN6
Electrical connections
  Main supply 3 x 16 A, 3 x L+N+PE
  Power consumption 7,5 kW (the full Gasmet CEMS including FTIR gas analyzer, PC, sampling unit, Gasmet O2 analyzer, sample probe, and heated lines 21 m)

Ftir Fourier Transform Infrared Flue Gas Toxicity Testing DeviceFtir Fourier Transform Infrared Flue Gas Toxicity Testing DeviceFtir Fourier Transform Infrared Flue Gas Toxicity Testing Device
Ftir Fourier Transform Infrared Flue Gas Toxicity Testing Device
Ftir Fourier Transform Infrared Flue Gas Toxicity Testing Device
Ftir Fourier Transform Infrared Flue Gas Toxicity Testing Device

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
1000000 RMB
Plant Area
>2000 square meters