KFZ Transformer With Load Loss and No Load Loss Tester
Product Description
KFZ Transformer With Load Loss and No Load Loss Tester is designed for transformer capacity, load loss and no load loss testing.
KFZ Transformer With Load Loss and No Load Loss Tester can measure following parameters of transformer: capacity, transformer type, no-load current, no-load loss, short circuit (load) loss and impedance voltage.
KFZ Transformer With Load Loss and No Load Loss Tester is reliable, accurate, simple for wiring and operation.
Product Parameters
No. |
Item Name |
KFZ Transformer With Load Loss and No Load Loss Tester |
1 |
Test Parameters |
Transformer capacity, no-load current, no-load loss, short circuit voltage, short circuit (load) loss |
2 |
Working power |
Input voltage |
185Vac~250Vac |
Allowable input voltage |
85Vac~264Vac |
Frequency |
50/60Hz |
Allowable frequency |
45Hz~65Hz |
Input power |
40VA |
3 |
AC voltage |
Range |
10~650V |
Resolution |
0.001V |
Accuracy |
0.2%±0.001V |
4 |
AC Current |
Range |
0.5~60A |
Resolution |
0.001A |
Accuracy |
0.2%±0.001A |
5 |
Frequency |
Range |
45Hz~65Hz |
Resolution |
0.001Hz |
Accuracy |
0.2%±0.001Hz |
6 |
Power |
Range |
0~39kW |
Resolution |
0.001kW |
Accuracy |
<±0.5%(CosΦ>0.1) ±1.0%(0.02<CosΦ<0.1) |
7 |
Capacity test range |
10kV Dry type transformer |
30kVA~3150kVA |
10kV Oil immersed transformer |
30kVA~3150kVA |
35kV Oil immersed transformer |
50kVA~31500kVA |
20kV Dry type transformer |
50kVA~2500kVA |
35kV Dry type transformer |
50kVA~2000kVA |
8 |
Environment |
Operating temperature |
-10ºC~+50ºC |
Storage temperature |
-25ºC~+70ºC |
Relative humidity |
5%~95% |
9 |
Dimension |
40cm*30cm*22cm |
10 |
Weight |
≈8kg (Excluding accessories) |
Features
Measurement range of voltage, current and capacity is wide, and measurement range can convert automatically. For example, the instrument can complete load test under full current of distribution transformer below 1000kVA. The load test of distribution transformers below 3150kV can be completed under 1/3 of the rated current (under 1/3 rated current, the instrument can be converted to the load loss parameter under the rated current).
When testing load and no load loss of three phase transformer, it can automatically determine whether the wiring is correct or not, and display vector of three phase voltage and current.
All test results can be automatically corrected. LCD 20 * 240 large screen.
Users can preset 40 sets sample parameters, and these parameters can be deleted or added at any time.
With real-time electronic clock, which can automatically record test date and time.
500 sets test data can be stored in the tester, meanwhile, users can connect the tester with computer to upload the data.
With built-in printer, users can print test result immediately after test.
Allows external current transformers or voltage transformers to extend measurement range, so it can test any kinds of transformers.
Detailed Photos
![Kfz Transformer with Load Loss and Empty Load Loss Tester](//www.micstatic.com/athena/img/transparent.png)
Packaging & Shipping
The whole set of KFZ Transformer With Load Loss and No Load Loss Tester is packed in one plywood case;
Packing dimension: 55cm * 45cm * 40cm;
Total weight: 18kg;
It is suitable for shipping by Express.
![Kfz Transformer with Load Loss and Empty Load Loss Tester](//www.micstatic.com/athena/img/transparent.png)
![Kfz Transformer with Load Loss and Empty Load Loss Tester](//www.micstatic.com/athena/img/transparent.png)
![Kfz Transformer with Load Loss and Empty Load Loss Tester](//www.micstatic.com/athena/img/transparent.png)