Six Phase Relay Testing Secondary Current Injection Test Set

Product Details
After-sales Service: Online Training for Operation and Installation
Warranty: 12 Months
Output: 6 Phase Voltage and 6 Phase Current
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
1000000 RMB
Plant Area
>2000 square meters
  • Six Phase Relay Testing Secondary Current Injection Test Set
  • Six Phase Relay Testing Secondary Current Injection Test Set
  • Six Phase Relay Testing Secondary Current Injection Test Set
  • Six Phase Relay Testing Secondary Current Injection Test Set
  • Six Phase Relay Testing Secondary Current Injection Test Set
  • Six Phase Relay Testing Secondary Current Injection Test Set
Find Similar Products

Basic Info.

Model NO.
PRT-PC6
Time Measurement Range
1ms-9999s
Functions
Measure Parameter of 3 and Six Phase Relay
Other Functions
Used as a Voltage Source Alone
Hardware
Signal Processor Microcomputer
Test Parameters
All Parameters of Six Phase Relay
Operation Mode
Panel or Computer Control
Description
Six Phase Relay Secondary Current Injection Tester
Application Field
Electrical Service, Relay Manufacturers
Features
Automatic Secondary Current Injection Test Set
Applicable Relays
Single Phase, Three Phase and Six Phase Relays
Display
Large LCD Screen Display
Packing Dimension
455 (mm) * 530 (mm) * 220 (mm)
Gross Weight
30kg
Power Supply
220V, 50Hz
Transport Package
Packed in Veneer Case
Specification
67*61*41CM
Trademark
Delta
Origin
China Mainland
HS Code
9031809090
Production Capacity
1000 Sets Secondary Current Injection Tester/Month

Packaging & Delivery

Package Size
69.00cm * 44.00cm * 73.00cm
Package Gross Weight
67.000kg

Product Description

RPT-PC6 Six Phase Relay Testing Secondary Current Injection Test Set

Description:

RPT-PC6 Six Phase Relay Testing Secondary Current Injection Test Set with standard 6 phase voltage and 6 phase current output, voltage 125V/phase, current 30A/phase, 6 phases in parallel can up to 180A.
With digital Signal Processor Microcomputer, it can not only test the traditional relays and protectors but also can test the modern microcomputer relays, especially for transformer differential protection and transfer equipment testing.

Features:
Classic Windows XP operating interface, 8.4 inch resolution of 800*600 TFT true color display.
Equipped with ultra-thin industrial keyboard and optical mouse, complete a variety of operations using keyboard or mouse the same as ordinary PC.
The main control board is DSP + FPGA architecture, 16 bit DAC output, generates high - density sine wave 2000 points each circle to fundamental wave, which greatly improve the wave quality and the accuracy of the test instrument.
Using high-fidelity linear amplifier. Both to ensure the accuracy of a low current, but also guarantee the stability of the high current.
USB directly connect with PC, without any adapter cable, easy to use.
Can be connected to a laptop computer (optional). Laptop computers and industrial machines use the same software, no need to re-learn the methods of operation.
With a separate DC auxiliary voltage source, output voltage 110V(1A),220V(0.6A), provides relays or protective devices which require DC power.
The software with self-calibrating function, which avoid to calibrate accuracy by adjusting relays after open the case, greatly improve the stability of the accuracy.

Functions:

RPT-PC6 Secondary Current Injection Test Set is suitable for following relays and protection devices testing:
Relay test Microprocessor-based protection device line protection Generator transformer protection Others
Signal relay Multi-stage over-current Differential protection Automatic synchronizing device
Time relay Over (less) voltage Field loss protection Protection device
Intermediate relay Sequence components voltage and current Excitation protection Bus bar differential protection
Reclosing relay Frequency devices Composite voltage locking ( direction) over-current (Reserve) Fiber-optic lines differential protection
Current relay Power directional protection    
Over (less) voltage relay Reclosing and conversion failure    
Sequence component relay Distance and zero sequence    
Synchronism-check (or phase comparison) relay Power frequency variation distance    
Extremely inverse current relay Composite voltage    
Differential relay Locking (direction) current    
Power (direction) relay Low cycle, low voltage load shedding device    
Impedance relay      
Synchronous relay      
Frequency relay      

Parameters:

No. Item Name RPT-PC6 Six Phase Relay Testing Secondary Current Injection Test Set
1 AC current source  
Current range 6x (0~30A)/phase
Current accuracy 0.5%
6 phase parallel current output 180A
Phase current working value for allowed long time 10A
Power 300VA/phase
Max. output power of 6 phases in parallel 900VA
Max. permitted work time of 6 phases in parallel 10S
Frequency range 0~1000Hz; accuracy: 0.001Hz
2 DC current source  
Current range 20A / phase
power 300VA/phase
accuracy 0.5%
3 AC voltage source  
Phase voltage output 6x( 0~125V)/phase
accuracy 0.5%
Line voltage output 0~250V
Phase voltage / Line voltage output power 70VA / 100VA
Frequency range 0~1000Hz
Frequency accuracy 0.001Hz
4 DC voltage source  
Phase voltage output range 0~±150V
accuracy 0.5%
Line voltage output range 0~±300V
Phase voltage / Line voltage output power 90VA / 180VA
5 Switch terminal  
Switch input terminals 8 pairs
Dead contact 1-20mA, 24V ac
Potential flip
  1. -6V DC low level                           15-250V DC high level
Switch output terminals 4 pairs, dead contact, rupturing capacity: 110V/2A, 220V/1A
6 Time measurement range  
Range 1ms-9999s
Accuracy 1ms
7 Dimension & weight  
Dimension 455 (mm)×530 (mm)×220 (mm)
Weight 30kg
8 Power AC220V±10%, 50Hz, 15A

Six Phase Relay Testing Secondary Current Injection Test SetSix Phase Relay Testing Secondary Current Injection Test Set
Six Phase Relay Testing Secondary Current Injection Test Set
Six Phase Relay Testing Secondary Current Injection Test Set
Six Phase Relay Testing Secondary Current Injection Test Set
Six Phase Relay Testing Secondary Current Injection Test Set
Six Phase Relay Testing Secondary Current Injection Test Set
Six Phase Relay Testing Secondary Current Injection Test Set

Six Phase Relay Testing Secondary Current Injection Test Set
Six Phase Relay Testing Secondary Current Injection Test Set
Six Phase Relay Testing Secondary Current Injection Test Set
Six Phase Relay Testing Secondary Current Injection Test Set

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier