CPT-III Fully Automatic Potentional Transformer Voltage Transformer CT PT Tester

Product Details
After-sales Service: Online Training for Operation and Installation
Warranty: 365 Days
Description: Potentional Voltage Transformer CT PT Tester
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
1000000 RMB
Plant Area
>2000 square meters
  • CPT-III Fully Automatic Potentional Transformer Voltage Transformer CT PT Tester
  • CPT-III Fully Automatic Potentional Transformer Voltage Transformer CT PT Tester
  • CPT-III Fully Automatic Potentional Transformer Voltage Transformer CT PT Tester
  • CPT-III Fully Automatic Potentional Transformer Voltage Transformer CT PT Tester
  • CPT-III Fully Automatic Potentional Transformer Voltage Transformer CT PT Tester
  • CPT-III Fully Automatic Potentional Transformer Voltage Transformer CT PT Tester
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Features
  • Detailed Photos
Overview

Basic Info.

Model NO.
CPT-III
Functions
Test Parameters of Voltage Transformer, CT PT, etc
Application Field
Electrical Industry, Transformer Manufacturer
Features
220V to 500kv CT PT Tester
Test Standards
IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C5
Current Output
0.001~5A(RMS)
Voltage Output
0.1~180V (AC)
Operation Mode
Large LCD Touch Screen
Power Output
500va
Max. Knee Voltage Measurement
45kv
Power Supply
AC 220V, 50Hz/60Hz
Delivery Lead Time
7 Days After The Order Is Confirmed
Shipping Method
Suggest to Ship by Air or Express
Trade Terms
EXW, Fob, DDU, Cit, etc.
Data Storage
1000 Groups Test Results
Transport Package
CT PT Tester Is Packed in Veneer Case
Specification
485mm * 356mm * 183mm
Trademark
Delta
Origin
China Mainland
HS Code
9031809090
Production Capacity
1000 Sets CT PT Tester / Month

Packaging & Delivery

Package Size
70.00cm * 50.00cm * 41.00cm
Package Gross Weight
40.000kg

Product Description

CPT-III Fully Automatic Potentional Transformer Voltage Transformer CT PT Tester

Product Description






CPT-III Fully Automatic Potentional Transformer Voltage Transformer CT PT Tester is used to measure all kinds of current transformer and voltage transformer.

CPT-III Fully Automatic Potentional Transformer Voltage Transformer CT PT Tester can calculate the ratio errors and phase angle errors of current transformer and voltage transformer at rated burden and working burden in one test.

CPT-III Fully Automatic Potentional Transformer Voltage Transformer CT PT Tester can automatically evaluate the test results according to the selected standard to determine whether the transformer is qualified.
CPT-III Fully Automatic Potentional Transformer Voltage Transformer CT PT Tester
 
Product Parameters
  • Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
  • Power supply: AC220V±10%, 50/60Hz±10%
  • Voltage output: 0.1~180V (AC)
  • Current output: 0.001~5A(RMS)
  • Power output: 500VA
  • Maximum knee voltage measurement: 45KV
  • PT ratio error measurement: typical error <0.05%, maximum error<0.1%
  • PT phase angle measurement: maximum error < 3min
  • Memory capacity: >1000 groups test results 
  • Working condition: temperature: -10ºC~50ºC, humidty: ≤90%
  • Size: 485mm * 356mm * 183mm, weight: <15kg
Parameters Range Error Resolution
Current 0~10A (automatically change range in 0.1/0.4/2/10A) <±0.1%+0.01%FS /
Voltage 0~200V (automatically change
range in 1V/10V/70V/200V)
<±0.1%+0.01%FS /
Turns Ratio 1~5000 <0.05% /
5000~35000 <0.1% /
Phase / ±2min 0.01min
Winding Resistance 0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm) <0.2%RDG+0.02%FS 0.1mΩ
Temperature -50~100 Celsius degree <3 Celsius degree /
CT Secondary Burden 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm) <0.2%RDG+0.02%FS 0.001ohm
PT Secondary Burden 0~80kohm (automatically change
range in 800ohm/8kohm/80kohm)
<0.2%RDG+0.02%FS 0.1ohm
PT Ratio 1~10000 <0.1% /
10000~35000 <0.2% /
 
Features
  • Make evaluation for test results according to selected standards.
  • Make word report for test result.
  • Make word reports one time for multi-group test records on the PC.
  • Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test.
  • Compare excitation curves with saved excitation curves in the same window.
Detailed Photos

CPT-III Fully Automatic Potentional Transformer Voltage Transformer CT PT TesterCPT-III Fully Automatic Potentional Transformer Voltage Transformer CT PT TesterCPT-III Fully Automatic Potentional Transformer Voltage Transformer CT PT Tester

  •  


CPT-III Fully Automatic Potentional Transformer Voltage Transformer CT PT Tester
CPT-III Fully Automatic Potentional Transformer Voltage Transformer CT PT Tester
CPT-III Fully Automatic Potentional Transformer Voltage Transformer CT PT Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier