ISO 9239-1, ASTM E648, Nfpa 253 Flooring Radiant Panel Tester

Product Details
After-sales Service: Life Time
Warranty: 12 Months
Max Diameter of Workpiece: <500mm
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
1000000 RMB
Plant Area
>2000 square meters
  • ISO 9239-1, ASTM E648, Nfpa 253 Flooring Radiant Panel Tester
  • ISO 9239-1, ASTM E648, Nfpa 253 Flooring Radiant Panel Tester
  • ISO 9239-1, ASTM E648, Nfpa 253 Flooring Radiant Panel Tester
  • ISO 9239-1, ASTM E648, Nfpa 253 Flooring Radiant Panel Tester
  • ISO 9239-1, ASTM E648, Nfpa 253 Flooring Radiant Panel Tester
  • ISO 9239-1, ASTM E648, Nfpa 253 Flooring Radiant Panel Tester
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Features
  • Application Field
  • Reference Standards
Overview

Basic Info.

Model NO.
RFP
Mass Scope of Workpiece
<900kg
Type
Material Testing Machine
Maxcapacity
<1000KN
Accuracy Grade
0.5
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Digital
Control
Computer Control
Weight
235kg
Power Source
AC220V
Oil Cylinder Position
Top
Reference Standards
ISO 9239-1, ASTM E648-17, Nfpa 253
Application Field
Building Material, Railway, Marine, Cable, etc.
Heat Flux Meter
0 ~ 50 Kw/M2
Item Name
ISO 9239-1, ASTM E648 Flooring Radiant Panel
Application
Measures The Critical Radiant Flux of Floorings
Burning Gas
Propane
Auxiliary Gas
Air Compressor Gas
Apparatus Dimension
1900mm (W) X 750mm X (H) X 2120mm (D)
Power Supply
220V, 10A, 50Hz
Delivery Lead Time
45 Days
Payment Term
30% in Advance, The Balance Before Delivery
Trade Term
Fob, CIF, DDU, etc.
Language
English
Condition
Totally New
OEM Service
Available
Transport Package
It Is Packed in Veneer Casse
Specification
1220 mm (W) x 550 mm (D) x 1920 mm (H)
Trademark
DELTA
Origin
China
HS Code
9031809090
Production Capacity
100 Sets / Month

Packaging & Delivery

Package Size
240.00cm * 110.00cm * 250.00cm
Package Gross Weight
300.000kg

Product Description

RFP ISO 9239-1, ASTM E648, NFPA 253 Flooring Radiant Panel Tester
 
Product Description
  1. RFP ISO 9239-1, ASTM E648, NFPA 253 Flooring Radiant Panel Tester is the cornerstone of the flooring materials reaction to fire tests in the Euroclass system. The test measures the spread of flame of the sample, under thermal exposure, using a radiant heat ignition source. The thermal exposure is that of a fire growing in the room of origin that through a door opening, radiates onto the floorings in an adjacent room or corridor.
  2. RFP ISO 9239-1, ASTM E648, NFPA 253 Flooring Radiant Panel Tester can also be used for tests to standards ASTM E648 and DIN 4102; Part 14.
Product Parameters
No. Item Name RFP ISO 9239-1, ASTM E648, NFPA 253 Flooring Radiant Panel Tester
1 Dimension 1900mm (W) x 750mm x (H) x 2120mm (D)
2 Weight 235kg
3 Power supply 230 volts Nominal 10 Amps
4 Ambient temperature Operating 10oC to 35oC
5 Burning gas Propane
6 Auxiliary gas Air compressor gas
Features
  1. The resulting test chamber is insulated with calcium silicate insulation board and is provided with a temperature resistant observation window.
  2. The stainless steel sample support assembly is mounted on a sliding platform to allow safe and easy loading of the test sample.
  3. The radiant heat is applied by means of a gas-fuelled panel, inclined at 30º, and directed at a horizontally mounted floor covering system specimen.
  4. The radiant panel generates a radiant energy flux distribution ranging from a nominal maximum of 10.9 kW/m2 to a minimum of 1.1 kW/m2.
  5. Dummy calibration specimen with holder, calibrated heat flux meter and mounting.
  6. The distance burned until flame-out is reached and converted, by calibration, into an equivalent critical radiant flux, in kW/m2.
  7. Heat Flux Meter: Range 0 ~ 50 kw/m2; Surface emissivity: ε=0.95± 0.05
  8. A smoke measuring system, according to DIN 50055, is mounted on a separate frame at the exhaust stack.
  9. Control Rack for convenience in use, allowing observation of the apparatus and controls during equipment set-up and calibration.
  10. Automatic ignition of the radiant panel and safety cut-out.
  11. Automatic moving T type ignition burner
  12. Stainless steel hood with smoke measurement ports.
 
Application Field
  • Building Materials;
  • Rail;
  • Automotive interior;
  • Others;
Reference Standards
  1. ISO 9239-1: Reaction to fire tests for floorings - Part 1: Determination of the burning behaviour using a radiant heat source;
  2. ASTM E648- 17: Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source;
ISO 9239-1, ASTM E648, Nfpa 253 Flooring Radiant Panel Tester
ISO 9239-1, ASTM E648, Nfpa 253 Flooring Radiant Panel Tester
ISO 9239-1, ASTM E648, Nfpa 253 Flooring Radiant Panel Tester

ISO 9239-1, ASTM E648, Nfpa 253 Flooring Radiant Panel Tester

ISO 9239-1, ASTM E648, Nfpa 253 Flooring Radiant Panel Tester

ISO 9239-1, ASTM E648, Nfpa 253 Flooring Radiant Panel Tester


Please contact us for quotation and more technical information.