Description: Power Transformer 10kv 12kv Power Factor Test Sets
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Portable 10kv 12kv Power Transformer Power Factor Test Set pictures & photos
Portable 10kv 12kv Power Transformer Power Factor Test Set
US $4,000-5,000 / Set
Min. Order: 1 Set
Gold Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Product Description
  • Product Parameters
  • Features
Overview

Basic Info.

Model NO.
TDT
Functions
Test Capacitance, Tan Delta, Dissipation Factor
Application Field
Electrical Industry, Transformer Manufacturer
Features
High Quality Power Factor Test Sets
Output Voltage
10kv or 12kv
Output Max. Current
200mA
Output Capacity
2000va
Self-Excited Power
AC 0V-50V/15A
Dimension
350mm*270mm*270mm
Weight
28kg
Power Supply
AC 220V, 50Hz
Delivery Lead Time
7 Days After The Order Is Confirmed
Shipping Method
Suggest to Ship by Air or Express
Trade Terms
EXW, Fob, DDU, Cit, etc.
Payment Term
30% as Deposit, The Balance Before Delivery
Transport Package
Power Factor Test Sets Are Packed in Veneer Case
Specification
400mm*350mm*200 mm, 7kg
Trademark
Delta
Origin
China Mainland
HS Code
9031809090
Production Capacity
1000 Sets Power Factor Test Set / Month

Packaging & Delivery

Package Size
56.00cm * 45.00cm * 44.00cm
Package Gross Weight
37.000kg

Product Description

TDT Portable 10kv 12kv Power Transformer Power Factor Test Set

Product Description
TDT Portable 10kv 12kv Power Transformer Power Factor Test Set is used to measure electrical loss tangent ( ) and capacitance of all kinds of high voltage electrical equipment in power plants, substations, laboratory, etc.

TDT Portable 10kv 12kv Power Transformer Power Factor Test Set is composed of a dielectric loss test bridge, a variable frequency power supply, a step-up transformer and a SF6 high stability standard capacitor, it is integrated structure.

TDT Portable 10kv 12kv Power Transformer Power Factor Test Set can also supply high voltage source for testing.

Frequency can be changed to 50Hz, 47.5Hz\52.5Hz, 45Hz\55Hz, 60Hz, 57.5Hz\62.5Hz, 55Hz\65Hz; thus, it can avoid interference of power frequency.
Portable 10kv 12kv Power Transformer Power Factor Test Set
 
Product Parameters
No. Item Name TDT Portable 10kv 12kv Power Transformer Power Factor Test Set
1 Output 0.5KV10KV Every 0.1kV
Precision 2%
Maximum current 200mA
Capacity 2000VA
2 Self-excited power AC 0V50V/15A 45HZ/55HZ 47.5HZ/52.5Hz
55HZ/65HZ 57.5HZ/62.5H
Automatic double frequency
3 Resolving power tgδ: 0.001% Cx: 0.001pF
4 Precision tgδ:±(Reading*1.0%+0.040%)   C x :±(Reading*1.0%+1.00PF)
5 Measuring range tgδ Unlimited
C x 15pF < Cx < 300nF
10KV Cx < 60  nF
5KV Cx < 150 nF
1KV Cx < 300 nF
CVT test Cx < 300 nF
6 CVT range 1010000 Accuracy: 0.1%
7 Dimension 350mm*270mm*270mm
8 Weight 28kg
9 Working enviorment -15ºC∽40ºC, RH<80%
10 Anti-interference Frequency conversion
11 Power Supply AC 220V±10%, 50Hz
Features
Portable 10kv 12kv Power Transformer Power Factor Test Set
Large LCD display: Equipped with a high-end full touch LCD screen.

Mass storage data: It can save 200 groups test results in the instrument.
Multiple test modes: The instrument has high pressure, high voltage, standard, positive connection method and reverse connection method, self excitation method and other methods as optional; high voltage in standard high voltage conditions (greater than 10kV) dielectric loss.

CVT test: The instrument can also test the full sealed CVT (capacitor voltage transformer) C1, C2 dielectric loss and capacitance, to achieve the C1, C2 simultaneous test. The instrument can also test the CVT ratio and voltage angle difference. It can accurately measure the dielectric loss and capacitance of CVT without dismantling the CVT high voltage lead.

High speed sampling signal: The inverter and sampling circuit of the instrument are all controlled by digital, and the output voltage is adjustable continuously.

Multi protection security: The instrument has many protection measures, such as input voltage fluctuation, output short circuit, over voltage, over current and temperature. The instrument also has the grounding detection function to ensure that no grounding equipment is not allowed to boost.


Portable 10kv 12kv Power Transformer Power Factor Test Set
Portable 10kv 12kv Power Transformer Power Factor Test Set
Portable 10kv 12kv Power Transformer Power Factor Test Set

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Portable 10kv 12kv Power Transformer Power Factor Test Set pictures & photos
Portable 10kv 12kv Power Transformer Power Factor Test Set
US $4,000-5,000 / Set
Min. Order: 1 Set
Gold Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Registered Capital
1000000 RMB
Plant Area
>2000 square meters