• Tdt-12kv Transformer Insulation Power Factor Tan Delta Diagnostics System
  • Tdt-12kv Transformer Insulation Power Factor Tan Delta Diagnostics System
  • Tdt-12kv Transformer Insulation Power Factor Tan Delta Diagnostics System
  • Tdt-12kv Transformer Insulation Power Factor Tan Delta Diagnostics System
  • Tdt-12kv Transformer Insulation Power Factor Tan Delta Diagnostics System
  • Tdt-12kv Transformer Insulation Power Factor Tan Delta Diagnostics System

Tdt-12kv Transformer Insulation Power Factor Tan Delta Diagnostics System

After-sales Service: Lifetime
Warranty: 365 Days
Max Diameter of Workpiece: Na
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Tdt-12kv Transformer Insulation Power Factor Tan Delta Diagnostics System pictures & photos
Tdt-12kv Transformer Insulation Power Factor Tan Delta Diagnostics System
US $4,000-5,000 / Set
Min. Order: 1 Set
Gold Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
Overview

Basic Info.

Model NO.
TDT-12kV
Mass Scope of Workpiece
<900kg
Type
Transformer Testing Equipment
Maxcapacity
Na
Accuracy Grade
0.5
Load Way
Electronic Load
Loading Method
Static Load
Display
Digital
Control
Manual Control
Weight
0-100Kg
Power Source
AC220V
Oil Cylinder Position
Na
Application
Measure Power Factor and Tan Delta of Transformer
Test Object
High Voltage Electrical Equipment Like Transformer
Special Function
Supply High Voltage Source for Testing
Variable Frequency Power Supply
50Hz, 47.5Hz\52.5Hz, 45Hz\55Hz, 60Hz, 57.5Hz\62.5h
Features
Insulation Power Factor and Tan Delta Test Syst
Output Voltage
10kv or 12kv
CVT Range
10 - 10000
Data Storage
200 Groups
OEM Service
Power Supply, Company Name, Model Can Be Changed
Dimension
350mm*270mm*270mm
Packing Dimension
510cm*520cm*550cm
Gross Weight
40kg
Delivery Lead Time
7 Days
Trade Term
EXW, Fob, DDU, CIF, CNF, etc.
Shipping Method
by Express or Air
Transport Package
Packed in Plywood Case
Specification
350mm*270mm*270mm
Trademark
Delta
Origin
China Mainland
HS Code
9031809090
Production Capacity
100 Sets / Month

Packaging & Delivery

Package Size
56.00cm * 45.00cm * 44.00cm
Package Gross Weight
35.000kg

Product Description

Product Description

TDT-12kV Transformer Insulation Power Factor Tan Delta Diagnostics System is used to measure electrical loss tangent and capacitance of all kinds of high voltage electrical equipment in power plants, substations, laboratory, etc.

It is composed of a dielectric loss test bridge, a variable frequency power supply, a step-up transformer and a SF6 high stability standard capacitor, it is integrated structure.

It can also supply high voltage source for testing.

Frequency can be changed to 50Hz, 47.5Hz\52.5Hz, 45Hz\55Hz, 60Hz, 57.5Hz\62.5Hz, 55Hz\65Hz; thus, it can avoid interference of power frequency.

Product Parameters
No. Item Name TDT-12kV Transformer Insulation Power Factor Tan Delta Diagnostics System
1 Output 0.5KV10KV Every 0.1kV
Precision 2%
Maximum current 200mA
Capacity 2000VA
2 Self-excited power AC 0V50V/15A 45HZ/55HZ 47.5HZ/52.5Hz/55HZ/65HZ 57.5HZ/62.5H Automatic double frequency
3 Resolving power tgδ: 0.001% Cx: 0.001pF
4 Precision tgδ:±(Reading*1.0%+0.040%)   C x :±(Reading*1.0%+1.00PF)
5 Measuring range tgδ Unlimited
C x 15pF < Cx < 300nF
10KV Cx < 60  nF
5KV Cx < 150 nF
1KV Cx < 300 nF
CVT test Cx < 300 nF
6 CVT range 1010000 Accuracy: 0.1%
7 Dimension 350mm*270mm*270mm
8 Weight 28kg
9 Working enviorment -15ºC∽40ºC, RH<80%
10 Anti-interference Frequency conversion
11 Power Supply AC 220V±10%, 50Hz
Detailed Photos
Tdt-12kv Transformer Insulation Power Factor Tan Delta Diagnostics System
Panel of TDT:
  1. Emergency stop
  2. U disk interface
  3. Total power switch
  4. Power input socket
  5. Cn socket
  6. Cx socket
  7. LCD
  8. Earthing terminal
  9. ES self-excited output
  10. Printer

Software of TDT:
Left photo is parameters setting under GST test, right photo is testing result.
Tdt-12kv Transformer Insulation Power Factor Tan Delta Diagnostics System
Tdt-12kv Transformer Insulation Power Factor Tan Delta Diagnostics System

Appearance of TDT:
Tdt-12kv Transformer Insulation Power Factor Tan Delta Diagnostics System
Tdt-12kv Transformer Insulation Power Factor Tan Delta Diagnostics System

Accessories:
Tdt-12kv Transformer Insulation Power Factor Tan Delta Diagnostics System
The accessories include:

Accessories case;

Red HV test cable;

Black LV test cable;

220V Power cable;

CVT self-excited power cable;

Ground cable;

Fuse;

Printing paper;
Packing:
Tdt-12kv Transformer Insulation Power Factor Tan Delta Diagnostics System
TDT is packed in one veneer case; 

Packing dimension: 510cm*520cm*550cm;
Gross weight: 40kg;

Suggest to delivery it through Express or Air;

TDT used in the Philippines:

Tdt-12kv Transformer Insulation Power Factor Tan Delta Diagnostics System
Tdt-12kv Transformer Insulation Power Factor Tan Delta Diagnostics System
Tdt-12kv Transformer Insulation Power Factor Tan Delta Diagnostics System

 


Tdt-12kv Transformer Insulation Power Factor Tan Delta Diagnostics System
Tdt-12kv Transformer Insulation Power Factor Tan Delta Diagnostics System

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Tdt-12kv Transformer Insulation Power Factor Tan Delta Diagnostics System pictures & photos
Tdt-12kv Transformer Insulation Power Factor Tan Delta Diagnostics System
US $4,000-5,000 / Set
Min. Order: 1 Set
Gold Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Registered Capital
1000000 RMB
Plant Area
>2000 square meters