• Automatic Electrical Transformer Oil Dissipation Factor Testing Equipment
  • Automatic Electrical Transformer Oil Dissipation Factor Testing Equipment
  • Automatic Electrical Transformer Oil Dissipation Factor Testing Equipment
  • Automatic Electrical Transformer Oil Dissipation Factor Testing Equipment
  • Automatic Electrical Transformer Oil Dissipation Factor Testing Equipment
  • Automatic Electrical Transformer Oil Dissipation Factor Testing Equipment

Automatic Electrical Transformer Oil Dissipation Factor Testing Equipment

After-sales Service: Lifetime
Warranty: 12 Months
Application: Test Dissipation Factor&DC Resistivity of Oil
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Automatic Electrical Transformer Oil Dissipation Factor Testing Equipment pictures & photos
Automatic Electrical Transformer Oil Dissipation Factor Testing Equipment
US $3,000-4,500 / Set
Min. Order: 1 Set
Gold Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Product Description
  • Product Parameters
  • Features
  • Detailed Photos
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
DLT
AC High Voltage Output
200V-2200V
DC High Voltage Output
00V-500V
Temperature Control Range
0-120 Centigrade
Features
High Test Accuracy and Fast Speed
Description
Transformer Oil Dissipation Factor Test Equipment
Operation Mode
LCD Touch Screen
Dimension
450mm*410mm*320mm
Net Weight
25kg
Power Supply
AC220V, 50Hz 60Hz
Delivery Lead Time
10 Days
Shipping Method
by Express or Air
Language
English
Display
Digital
OEM Service
Yes
Transport Package
Dissipation Factor Tester Packed in Veneer Case
Specification
450mm*410mm*320mm
Trademark
Delta
Origin
China Mainland
HS Code
9031809090
Production Capacity
1000 Sets / Month

Packaging & Delivery

Package Size
56.00cm * 45.00cm * 33.00cm
Package Gross Weight
37.000kg

Product Description

DLT-I Automatic Electrical Transformer Oil Dissipation Factor Testing Equipment
 
Product Description

DLT-I Automatic Electrical Transformer Oil Dissipation Factor Testing Equipment is used to measure the dielectric loss factor and DC resistivity of insulating oil.

It adopts an integrated structure and integrates main components such as dielectric loss oil cup, temperature controller, temperature sensor, dielectric loss test bridge, AC test power supply, standard capacitor, high resistance meter, and DC high voltage source.

It adopts all-digital technology inside, all intelligent automatic measurement, equipped with large-screen 5.7-inch TFT pure color LCD touch display, full Chinese menu, test results can be automatically stored and printed out, the operator does not need to Professional training is required to be proficient in use.

Product Parameters
Item Name DLT-I Automatic Electrical Transformer Oil Dissipation Factor Testing Equipment
AC High Voltage Output 200V-2200V, continuously adjustable
DC High Voltage Output 00V-500V, continuously adjustable
Power consumption 100W
Temperature Control Range 0~120ºC
Temperature Measuring Error ±0.5ºC
Measuring Range Capacitance: 5PF-200PF
Relative permittivity 1.000~30.000
Dielectric loss factor 0.00001~100
DC resistivity: 2.5 MΩm~20 TΩm
Resolution Capacitance 0.01pF
Relative permittivity 0.001
Dielectric loss factor 0.00001
Accuracy Capacitance ± (1% reading + 0.5pF)
Relative permittivity ±1% of reading
Dielectric loss factor ±(1% reading+0.0001
DC Resistivity ±10% of reading
Dimension 450mm×410mm×320mm
Net Weight 25KG
Condition of Use -5ºC-40ºC RH<80%
Power Supply AC 220V±10%, 50Hz/60Hz ±1%
Features
Using large-screen TFT pure color LCD touch display, the display is clear. With a simple setup, the instrument can perform the test automatically. And automatically store and print test results.

With a real-time clock, the test date and time can be saved, displayed and printed with the test results.

It is convenient to set test parameters. The temperature setting range is 0
~120ºC, the AC voltage setting range is 200~2200V, and the DC voltage setting range is 0~500V.
Automatic Electrical Transformer Oil Dissipation Factor Testing Equipment
Automatic Electrical Transformer Oil Dissipation Factor Testing Equipment
The oil cup adopts a three-electrode structure in accordance with the national standard GB/T5654-2007, and the distance between the electrodes is 2mm, which can eliminate the influence of stray capacitance and leakage on the dielectric loss test results.

The instrument adopts intermediate frequency induction heating and PID temperature control algorithm. This heating method has the advantages of non-contact between the oil cup and the heating body, uniform heating, fast speed, and convenient control, so that the temperature is strictly controlled within the preset temperature error range.

The internal standard capacitor is SF6 gas-filled three-point-pole capacitor. The dielectric loss and capacitance of the capacitor are not affected by ambient temperature and humidity, so that the accuracy of the instrument can be guaranteed after long-term use.


The AC test power supply adopts the AC-DC-AC conversion method, which effectively avoids the influence of the mains voltage and frequency fluctuations on the accuracy of the dielectric loss test. Even if the generator generates electricity, the instrument can run correctly.

Perfect protection function. When there is overvoltage, overcurrent, or high voltage short circuit, the instrument can quickly cut off the high voltage and issue a warning message. When the temperature sensor fails or is not connected, a warning message is issued. There is a temperature limit relay in the intermediate frequency induction heating furnace. When the temperature exceeds 120 degrees, the relay is released and the heating stops.

Empty electrode cup calibration function. Measure the capacitance and dielectric loss factor of the empty electrode cup to judge the cleaning and assembly condition of the empty electrode cup. Calibration data is automatically saved to facilitate accurate calculations of relative permittivity and DC resistivity.

DLT-I Transformer Oil Dissipation Factor Tester is based on the RAM9 platform, with high test accuracy and fast speed.

Detailed Photos
Automatic Electrical Transformer Oil Dissipation Factor Testing Equipment
Automatic Electrical Transformer Oil Dissipation Factor Testing Equipment
Packaging & Shipping
Automatic Electrical Transformer Oil Dissipation Factor Testing Equipment
DLT-I Automatic Electrical Transformer Oil Dissipation Factor Testing Equipment is packed in one veneer case, which is firm enough for oversea delivery.


Automatic Electrical Transformer Oil Dissipation Factor Testing Equipment
Automatic Electrical Transformer Oil Dissipation Factor Testing Equipment
Automatic Electrical Transformer Oil Dissipation Factor Testing Equipment

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Automatic Electrical Transformer Oil Dissipation Factor Testing Equipment pictures & photos
Automatic Electrical Transformer Oil Dissipation Factor Testing Equipment
US $3,000-4,500 / Set
Min. Order: 1 Set
Gold Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Registered Capital
1000000 RMB
Plant Area
>2000 square meters