Prt-PC3 220V 50Hz Transformer 3 Phase Relay Electrical Test Instrument

Product Details
Customization: Available
After-sales Service: Online Training for Operation and Installation
Warranty: One Year
Shipping
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Guarantee
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
ODM Services
The supplier provides ODM services
to see all verified strength labels (9)
  • Prt-PC3 220V 50Hz Transformer 3 Phase Relay Electrical Test Instrument
  • Prt-PC3 220V 50Hz Transformer 3 Phase Relay Electrical Test Instrument
  • Prt-PC3 220V 50Hz Transformer 3 Phase Relay Electrical Test Instrument
  • Prt-PC3 220V 50Hz Transformer 3 Phase Relay Electrical Test Instrument
  • Prt-PC3 220V 50Hz Transformer 3 Phase Relay Electrical Test Instrument
  • Prt-PC3 220V 50Hz Transformer 3 Phase Relay Electrical Test Instrument
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Functions
  • Packaging & Shipping
  • After Sales Service
Overview

Basic Info.

Model NO.
PRT-PC3
Description
Transformer 3 Phase Relay Test Instrument
Functions
Measure Parameter of Three Phase Relay
Other Functions
Used as a Voltage Source Alone
Application Field
Electrical Service, Three Phase Relay Manufacturer
Features
Transformer 3 Phase Relay Test Instrument
Test Parameters
Most Parameters of Three Phase Protection Relay
Operation Mode
Micro-Computer Control
Hardware
DSP Micro-Computer Controller
AC Output
0~30A * 3
DC Output
0 ~ 10A
Time Measurement
0.1ms - 9999s
Switch Parameters Input
7 Ways
Packing Dimension
67*61*41cm
Gross Weight
44kg
Power Supply
220V, 50Hz
Transport Package
It Is Packed in Veneer Case
Specification
Gross weight 47kg
Trademark
Delta
Origin
China Mainland
HS Code
9031809090
Production Capacity
1000 Sets / Month

Packaging & Delivery

Package Size
56.00cm * 35.00cm * 70.00cm
Package Gross Weight
47.000kg
Lead Time
7 days (1 - 1 Sets)
To be negotiated ( > 1 Sets)

Product Description

PRT-PC3 Transformer 3 Phase Relay 220V 50Hz Electrical Test Instrument
Product Description
The PRT-PC3 Transformer 3 Phase Relay 220V 50Hz Electrical Test Instrument is a top-notch solution designed to rigorously assess the relay units within relay protection systems. Additionally, it serves brilliantly as a versatile three-phase AC/DC voltage and current source.

This versatile instrument expertly tests protection relays based on both voltage and current operations, ensuring high precision and reliability.

Its core functionalities include calibrating voltage and current operation relays, inspecting secondary circuits, testing circuit breaker trip values, and measuring the switch-on and switch-off timings of circuit breakers, amongst other capabilities.

Boasting affordability, ease of use, and dependable performance, this device is perfectly suited for secondary circuit testing applications.
Prt-PC3 220V 50Hz Transformer 3 Phase Relay Electrical Test Instrument

 

Product Parameters
 
  PRT-PC3 Transformer 3 Phase Relay 220V 50Hz Electrical Test Instrument
No. Items Specifications
Alternating Current(AC) output
1 Output accuracy 0.5magnitude
2 Phase current output (effective value) 0~30A
3 Three parallel phase current output (effective value) 0~90A
4 Phase current value with long time under permission (effective value) 10A
5 Phase current maximum power output 420VA
6 Three parallel phase current maximum power output 900VA
7 Three parallel phase current maximum work time 10s
8 Frequency range (base wave) 20~1000Hz
9 Harmonic frequency number 1~20 time
Direct Current(DC) output
1 Output accuracy 0.5magnitude
2 Current output 0 ~ ± 10 A/each phase
0 ~ ± 30 A/every three parallel
3 Maximum output of load voltage 20v
Alternating Voltage output
1 Output accuracy 0.5magnitude
2 Phase voltage output (RMS) 0 ~ 120v
3 Line voltage output (RMS) 0 ~ 240v
4 Phase voltage/line voltage power output 80VA/100VA
5 Frequency range (base wave) 20 ~ 1000Hz
6 Harmonic frequency number 1 ~ 20 times
Direct voltage output
1 Output accuracy 0.5magnitude
2 Phase voltage output amplitude 0 ~ +160v
3 Line voltage output amplitude 0 ~ + 320v
4 Phase voltage/line voltage power output 70VA/140VA
 
1 AC current and voltage error <0.5%RDG+0.05%FS
2 DC current error <0.5%RDG+0.05%FS
3 DC voltage error 1%RDG+0.1%FS
4 Binary input Active node 0~250V, 0~6V for "0", 6~250V for "1", passive node: 20mA max
5 Binary output DC 220V/0.2A, AC 220V/0.5A
The switch quantity and time measurement
1 Switch parameters input 7 ways; Empty contact: 1~20mA, 24v;
Power contact access: "0": 0-+6V;
"1":+11 V-+250V;
2 Switch parameters output 2 couples DC: 220V/0.2A; AC: 220V/0.5A
3 Time measurement Measuring range: 0.1ms - 9999s / 0.1ms
 
1 Power supply AC220V ± 10%, 50Hz/60Hz
2 Environment temperature 0~50°C
3 Humidity ≤85%RH
4 Weight <18KG
Functions
Testing protection relay units based on AC current and voltage.

Evaluation of protection relay units based on DC current and voltage.

Frequency-based protection relay unit testing.

Harmonic protection relay unit testing for dynamic analysis.

Testing of differential protection relay units for precise fault detection.

Zero-sequence protection relay unit testing for unbalance identification.

Distance protection relay unit testing for accurate fault localization.

Simulating power system network faults for comprehensive analysis.
Prt-PC3 220V 50Hz Transformer 3 Phase Relay Electrical Test Instrument
 
Packaging & Shipping
Prt-PC3 220V 50Hz Transformer 3 Phase Relay Electrical Test Instrument
The PRT-PC3 Transformer 3 Phase Relay 220V 50Hz Electrical Test Instrument comes securely packed in a robust veneer case for optimal protection.

Gross Weight: 56cm*35cm*70cm

Dimension: 47kg

 

After Sales Service
Prt-PC3 220V 50Hz Transformer 3 Phase Relay Electrical Test Instrument
1. Our products come with a One-year warranty for peace of mind.

2. During the warranty period, any quality issues will be repaired by Delta Technology at no additional cost;

3. After the warranty period, we offer lifetime maintenance services, charging only for necessary accessories;

4. A comprehensive user manual accompanies each tester, and some models include demo materials for user review.

5. For operational queries, we provide online video training. Users are also welcome to visit our factory for free in-person training sessions.


Prt-PC3 220V 50Hz Transformer 3 Phase Relay Electrical Test Instrument
Prt-PC3 220V 50Hz Transformer 3 Phase Relay Electrical Test Instrument
Prt-PC3 220V 50Hz Transformer 3 Phase Relay Electrical Test Instrument

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Send Inquiry
Chat Now