• Sbi Measurement Flame Retardant Properties Tester BS En 13823
  • Sbi Measurement Flame Retardant Properties Tester BS En 13823
  • Sbi Measurement Flame Retardant Properties Tester BS En 13823
  • Sbi Measurement Flame Retardant Properties Tester BS En 13823
  • Sbi Measurement Flame Retardant Properties Tester BS En 13823
  • Sbi Measurement Flame Retardant Properties Tester BS En 13823

Sbi Measurement Flame Retardant Properties Tester BS En 13823

After-sales Service: Response on Customer′s Query Within 12 Hours
Warranty: 12 Months
Item Name: Sbi Measurement Flame Retardant Properties Tester
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Sbi Measurement Flame Retardant Properties Tester BS En 13823 pictures & photos
Sbi Measurement Flame Retardant Properties Tester BS En 13823
US $50,000-80,000 / Set
Min. Order: 1 Set
Gold Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Product Description
  • Reference Standards
  • Features
  • Product Parameters
  • Testing Results
  • Detailed Photos
Overview

Basic Info.

Model NO.
SBI
Application
Test Reaction to Fire Behavior of Building Product
Application Field
Building Material
Reference Standards
ISO 9239-1, ASTM E648-17
Apparatus Dimension
3000 mm (W) X 4500 mm (H) X 3000 mm
Weight
650kg
Power Supply
220V, 10A, 50Hz
Features
BS En 13823 Flame Retardant Properties Tester
Delivery Lead Time
2 Months
Trade Term
EXW, Fob, DDU, CNF, CIF, etc.
Payment Term
30% T/T as Deposit, The Balance Before Delivery
Control Mode
Through Computer
Language
English
Condition
Totally New
OEM Service
Available
Transport Package
Flame Retardant Tester Is Packed in Veneer Casse
Specification
3000 mm (W) x 4500 mm (H) x 3000 mm
Trademark
DELTA
Origin
China
HS Code
9031809090
Production Capacity
10 Sets / Month

Packaging & Delivery

Package Size
800.00cm * 800.00cm * 800.00cm
Package Gross Weight
8000.000kg

Product Description

SBI Measurement Flame Retardant Properties Tester BS EN 13823
 
Product Description
  1. The Single Burning Item (SBI) is a method of test for determining the reaction to fire behavior of building products (excluding floorings) when exposed to the thermal attack by a single burning item (a sand-box burner supplied with propane).
 
  1. The specimen is mounted on a trolley that is positioned in a frame beneath an exhaust system. The reaction of the specimen to the burner is monitored instrumentally and visually. Heat and smoke release rates are measured instrumentally and physical characteristics are assessed by observation.
Sbi Measurement Flame Retardant Properties Tester BS En 13823

 

Reference Standards
  • EN 13501;
  • EN 13823;
Features
  • SBI Flame Retardant Properties Tester consists of a trolley, a fixed frame, a gas collecting hood, collector, J type exhaust pipe, centrifugal fan, wind speed control device, the comprehensive measurement section, gas analysis cabinet, data acquisition system;
  • The trolley can be installed with two vertical sample specimens. The bottom of the vertical angle is a sand box burner. The surface ignition method is adopted, and the flame detection system is equipped as a flameout protection device;
  • The fixed frame support the gas collecting hood. The frame is fixed with an auxiliary burner and equipped with a flame detecting system as a flameout protection device;
  • Stainless steel gas collector, located at the top of the fixed frame, used to collect combustion gases;
  • Stainless steel J type smoke exhaust pipe, the inner diameter is (315 + 5) mm  with 50mm high temperature resistant mineral cotton insulation;
  • The smoke exhaust system shall continuously exhaust smoke at the speed of 0.50m3/s-0.65 m3/s, and be regulated by frequency conversion;
  • Mass flow controller, measuring range of 0g/s-2.5g/s, reading accuracy of not less than 1.5%;
  • Gas supply can be automatically controlled to flow rate of 647mg/s and 2000mg/s, the gas control system can guarantee the speed of gas supply in the process of test changes should not exceed 5mg/s, to ensure the heat output of 30.7 + 2kW;
  • The flue gas sampling system consists of an ash filter, a cold trap, two drying columns, a sampling pump and a peristaltic pump, so as to effectively make sample gas clean and dry;
  • Paramagnetic oxygen analyzer, measuring range of 0-25%, measuring oxygen concentration in the gas, the concentration range of 0-25%, T90<12 seconds; Non dispersive infrared CO2 analyzer: CO2:0 ~ 10%;
  • A pipeline with a length of 2155mm, equipped with a pressure probe, three thermocouples, a gas sampling probe, and a white light system;
  • Two-way probe, with the range of at least (0-100) Pa and accuracy of 2Pa inlet pressure sensor connected. The response time of the pressure sensor 90% output is at most 1s;
  • The light system is incandescent type, with (2900 + 100) K color temperature,and the flexible joint is installed on the side of the exhaust pipe;
  • Silicon photodiode detector, with 0.1% linear stability;
  • The air is introduced into the side tube to maintain the cleanliness of the optical device, which can be accomplished by compressed air;
Product Parameters
No. Item Name SBI Flame Retardant Properties Tester
1 Dimension 3000 mm (W) x 4500 mm (H) x 3000 mm
2 Weight 650kg

Software Features:

Provide the following calibration and operation interface:
  • O2/CO2 analyzer calibration: O2/CO2 output noise and drift calibration
  • Calibration of optical systems: noise and drift calibration of smoke measurement systems
  • Optical system calibration: filter calibration
  • Air volume calibration: air volume control range calibration
  • Ladder calibration and heptane calibration
Heat output ladder calibration meet the following requirements:
  • The delay time of the O2/CO2 analyzer is not more than 30s;
  • The response time of the O2/CO2 analyzer is not more than 12s;
  • The response time of the burner switch is not more than 12s;
  • The temperature response time shall not exceed 6s;
  • The ratio Q gas 30s (T) /HRR30s (T), (T) should be continuous (100 + 5)%;
  • The difference between the average of HRR step 2 and the average of HRR step 3 is not more than 0.5kW.
Heptane calibration results:
The calorific value of unit mass heptane should be THR/m (4456 + 222.8) MJ/kg;

 
Testing Results
  • Average rate of heat release[RHRav(t)]

    Total Heat Release[THR(t)]

    1000 * [RHRav(t)/(t-300)]

    Fire Growth Rate Index[FIGRA]

    Total Heat Release[THR600s]

    Occurrence of Lateral Flame Spread
    RSPav(t)

    Total Smoke Production[TSP(t)]

    10000 * [RSPav(t)/(t-300)]

    Smoke Growth Rate Index[SMOGRA]

    Total Smoke Production[TSP600s]
    Sbi Measurement Flame Retardant Properties Tester BS En 13823
     
    Detailed Photos
    Sbi Measurement Flame Retardant Properties Tester BS En 13823
    Sbi Measurement Flame Retardant Properties Tester BS En 13823

    Sbi Measurement Flame Retardant Properties Tester BS En 13823

Please contact us for quotation and more technical information.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Sbi Measurement Flame Retardant Properties Tester BS En 13823 pictures & photos
Sbi Measurement Flame Retardant Properties Tester BS En 13823
US $50,000-80,000 / Set
Min. Order: 1 Set
Gold Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Registered Capital
1000000 RMB
Plant Area
>2000 square meters